Razón española, Edizioni 21-26Fundación Balmes, 1983 |
Dall'interno del libro
Risultati 1-3 di 67
Pagina 242
... ( Reagent for Al , Be , and other metal ions ) Flavanol OH ( Reagent for Zr and Sn ) OH HO N = N Alizarin garnet R ( Reagent for Al , F ̄ ) O OH C- H Benzoin ( Reagent for B , Zn , Ge , and Si ) SO , Na Selected fluorometric reagents and ...
... ( Reagent for Al , Be , and other metal ions ) Flavanol OH ( Reagent for Zr and Sn ) OH HO N = N Alizarin garnet R ( Reagent for Al , F ̄ ) O OH C- H Benzoin ( Reagent for B , Zn , Ge , and Si ) SO , Na Selected fluorometric reagents and ...
Pagina 697
... reagent volume ( or of time if the reagent is generated by a con- stant - current coulometric process ) . Plots of the data on either side of the equivalence point are straight lines with differing slopes ; the end point is established ...
... reagent volume ( or of time if the reagent is generated by a con- stant - current coulometric process ) . Plots of the data on either side of the equivalence point are straight lines with differing slopes ; the end point is established ...
Pagina 876
... Reagent layer 2 Acid - base indicator Cellulose acetate Transparent support Reference solution well Reference electrode From : T. L. Shirey. Sample Sample 100 μm Spreading and reflecting layer 10 μm Reagent layer Glucose oxidase ...
... Reagent layer 2 Acid - base indicator Cellulose acetate Transparent support Reference solution well Reference electrode From : T. L. Shirey. Sample Sample 100 μm Spreading and reflecting layer 10 μm Reagent layer Glucose oxidase ...
Sommario
Contents | 1 |
Elementary Electronics | 30 |
Microcomputers and Microprocessors in Chemical Instrumentation | 80 |
Copyright | |
46 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Parole e frasi comuni
absorbance absorption acid amplifier Anal analysis analyte analytical signal anode applications atoms beam Beer's law Calculate cathode cell Chem chemical chromatography circuit column components compounds concentration constant containing coulometric curve detector determination device dispersion effect elec electrical electrode elements emission employed energy Equation example excited filter flame fluorescence frequency function hydrogen infrared input instruments ionization iron(II liquid magnetic mass mass spectrometer measurements membrane ment methods mobile phase molar absorptivities molecular molecules monochromator obtained operational amplifier optical output oxidation particles peak photomultiplier plate polarized polarography potential prism protons pulse quantitative radiation Raman range reaction reagent refractive refractive index region relative rotation sample sensitivity shown in Figure signal slit solution solvent species spectra spectrometer spectrophotometer spectroscopy spectrum standard deviation stationary phase surface temperature tion titration trode tube typical ultraviolet V₁ vibrational voltage wave wavelength X-ray