Analytical Chemistry, Volume 4Wiley, 2003 - 828 pagine This text is designed for the undergraduate one-term Quantitative Analysis course (sometimes called Analytical Chemistry) for students majoring in Chemistry and related fields. It deals with principles and techniques of quantitative analysis. Examples of analytical techniques are drawn from such areas as life sciences, clinical chemistry, air and water pollution, and industrial analyses.The Sixth Edition is extensively revised and updated with a more modern flavor and a new, two-color design. |
Dall'interno del libro
Risultati 1-3 di 76
Pagina 353
... chloride in 0.100 M ethylenediamine . Also calculate the equilibrium concentrations of Ag ( en ) * and Ag ( en ) , * . MASS BALANCE CALCULATIONS 7. Calculate the solubility of AgIO , in 0.100 M HNO3 , using the mass balance approach ...
... chloride in 0.100 M ethylenediamine . Also calculate the equilibrium concentrations of Ag ( en ) * and Ag ( en ) , * . MASS BALANCE CALCULATIONS 7. Calculate the solubility of AgIO , in 0.100 M HNO3 , using the mass balance approach ...
Pagina 371
... chloride ion in solution . Note that , as the activity of chloride increases , the potential decreases . This is true of any electrode measuring an anion - the opposite for a cation electrode . A silver wire is coated with silver chloride ...
... chloride ion in solution . Note that , as the activity of chloride increases , the potential decreases . This is true of any electrode measuring an anion - the opposite for a cation electrode . A silver wire is coated with silver chloride ...
Pagina 378
... chloride salt bridge , at or near saturation , is usually employed , except when these ions may interfere in a determination . Ammonium chloride or potassium nitrate may be used if the potas- sium or chloride ion interferes . A commonly ...
... chloride salt bridge , at or near saturation , is usually employed , except when these ions may interfere in a determination . Ammonium chloride or potassium nitrate may be used if the potas- sium or chloride ion interferes . A commonly ...
Sommario
Chapter | 1 |
The use of spreadsheets for plotting curves and perform Least squares equation | 3 |
Chapter | 8 |
Copyright | |
42 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Parole e frasi comuni
absorbance absorption acetic activity coefficients AgCl agent analysis Analytical Chemistry atomic balance base buffer buret calcium Calculate calibration curve capillary cell Chapter Chem chemical chloride chromatography coefficient color column complex compounds concentration contains detector determined dilute dissociation dissolved EDTA electrode electrolyte end point enzyme Equation equilibrium constant equivalence point error example f wt Fe2+ filter flame fluorescence formula weight gas chromatography gravimetric half-reaction HOAc hydrogen indicator instruments ion-selective electrode ionic strength ionization iron(II laboratory liquid measurements metal method millimoles mmol mmol/mL molarity molecules moles NaOH obtained oxidizing particles peak phase pipet plot potassium potential precipitate prepared protein proton radiation react reaction reagent redox salt sample serum significant figures silver sodium sodium hydroxide solubility solvent species spectrometry spectrophotometry spreadsheet standard deviation substance technique temperature tion titration titration curve volume volumetric flask wavelength