Chemical Instrumentation: A Systematic Approach to Instrumental AnalysisAddison-Wesley Publishing Company, 1960 - 653 pagine |
Dall'interno del libro
Risultati 1-3 di 34
Pagina 279
... Capacitance . Essentially , capacitance in a d - c circuit blocks the current . In contrast to the behavior of an inductor , a capacitor allows charge to flow only when the current intensity is changing , and ... CAPACITANCE 11-6 Capacitance.
... Capacitance . Essentially , capacitance in a d - c circuit blocks the current . In contrast to the behavior of an inductor , a capacitor allows charge to flow only when the current intensity is changing , and ... CAPACITANCE 11-6 Capacitance.
Pagina 283
... capacitance C must be in farads and the fre- quency ƒ in cycles per second . EXAMPLE 1. A capacitor of 20 ... capacitance , the type of dependence is exactly opposite to that found for an inductance . A small capacitance will have a ...
... capacitance C must be in farads and the fre- quency ƒ in cycles per second . EXAMPLE 1. A capacitor of 20 ... capacitance , the type of dependence is exactly opposite to that found for an inductance . A small capacitance will have a ...
Pagina 429
... capacitances . The cell - wall resistance R , is presumed very large relative to solution resistance R , and is ignored . The capacitance of the glass walls C , is small relative to the capacitance of the solution Cs , but is not ...
... capacitances . The cell - wall resistance R , is presumed very large relative to solution resistance R , and is ignored . The capacitance of the glass walls C , is small relative to the capacitance of the solution Cs , but is not ...
Sommario
THE SCIENCE OF INSTRUMENTATION | 1 |
ERRORS OF MEASUREMENT | 14 |
CHAPTER 3 | 37 |
Copyright | |
38 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Chemical Instrumentation: A Systematic Approach to Instrumental Analysis Howard A. Strobel Visualizzazione estratti - 1960 |
Parole e frasi comuni
absorbance absorption acid amplifier analysis analyzed angle anode applied atoms band beam Beer's law calibration calomel capacitance capacitor cathode cell Chem chemical circuit components concentration conductance constant coulometric curve detection detector determined device diffusion diode dispersion drop effect electrical electrode electrolysis electron tube emission end point energy error example filter frequency galvanometer glass grid incident input instrument intensity ionization ions layer liquid measurement mercury metal meter method mixture molecules obtained operation optical optical rotation output oxidized particles pH meter photometer phototube plate current platinum polarized polarographic potential potentiometer precision prism procedure quantitative radiation range reactance reaction reflection refractive index region resistance resistor result rotation sample sawtooth wave scattering schematic Section sensitivity shown in Fig signal slit solution solvent species spectra spectrophotometer spectrum standard substance techniques temperature thyratron tion titration transistor triode variable vibrational voltage wave wavelength