Pagina 281
... capacitor combination , a time constant . is also desirable . It serves as a measure of the interval required to charge ( or discharge ) a capacitor through a resistance and also for a d - c capacita- tive circuit to reach steady ...
... capacitor combination , a time constant . is also desirable . It serves as a measure of the interval required to charge ( or discharge ) a capacitor through a resistance and also for a d - c capacita- tive circuit to reach steady ...
Pagina 282
... capacitor at the left are two sizes of " postage - stamp " mica capacitors . A high - voltage mica capacitor is at the right in front of the box - type capacitor . In front of it are three kinds of ceramic capacitors . ( Courtesy of ...
... capacitor at the left are two sizes of " postage - stamp " mica capacitors . A high - voltage mica capacitor is at the right in front of the box - type capacitor . In front of it are three kinds of ceramic capacitors . ( Courtesy of ...
Pagina 283
... capacitor . When the potential difference across the capacitor is zero , the rate of flow of charge will be highest . When the current falls to zero , the capacitor will be fully charged , and the voltage will be at the maxi- mum . The ...
... capacitor . When the potential difference across the capacitor is zero , the rate of flow of charge will be highest . When the current falls to zero , the capacitor will be fully charged , and the voltage will be at the maxi- mum . The ...
Sommario
THE SCIENCE OF INSTRUMENTATION | 1 |
ERRORS OF MEASUREMENT | 14 |
CHAPTER 3 | 37 |
Copyright | |
38 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Chemical Instrumentation: A Systematic Approach to Instrumental Analysis Howard A. Strobel Visualizzazione estratti - 1960 |
Parole e frasi comuni
absorbance absorption acid amplifier analysis analyzed angle anode applied atoms band beam Beer's law calibration calomel capacitance capacitor cathode cell Chem chemical circuit components concentration conductance constant coulometric curve detection detector determined device diffusion diode dispersion drop effect electrical electrode electrolysis electron tube emission end point energy error example filter frequency galvanometer glass grid incident input instrument intensity ionization ions layer liquid measurement mercury metal meter method mixture molecules obtained operation optical optical rotation output oxidized particles pH meter photometer phototube plate current platinum polarized polarographic potential potentiometer precision prism procedure quantitative radiation range reactance reaction reflection refractive index region resistance resistor result rotation sample sawtooth wave scattering schematic Section sensitivity shown in Fig signal slit solution solvent species spectra spectrophotometer spectrum standard substance techniques temperature thyratron tion titration transistor triode variable vibrational voltage wave wavelength