Chemical Instrumentation: A Systematic Approach to Instrumental AnalysisAddison-Wesley Publishing Company, 1960 - 653 pagine |
Dall'interno del libro
Risultati 1-3 di 77
Pagina 214
... cell . 4 , sample cell . 5 , reference cell ( filter cell ) . 6 , compensator cell . 8 , bridge incorporating bolometers ( 7 ) as arms . 9 , recorder . with that of an identical beam passing through both sample cell and a reference cell ...
... cell . 4 , sample cell . 5 , reference cell ( filter cell ) . 6 , compensator cell . 8 , bridge incorporating bolometers ( 7 ) as arms . 9 , recorder . with that of an identical beam passing through both sample cell and a reference cell ...
Pagina 415
... cell filled with solution of specific conductivity K is K = l ᎪᎡ ( 14-1 ) To use a cell , only the ratio l / A , termed the cell constant , need be known . In practice , this constant is easily determined by measuring the resistance ...
... cell filled with solution of specific conductivity K is K = l ᎪᎡ ( 14-1 ) To use a cell , only the ratio l / A , termed the cell constant , need be known . In practice , this constant is easily determined by measuring the resistance ...
Pagina 434
... cell , influence of fluctuations in flow rate may often be compensated by a prop- erly designed balancing cell ( Section 14-14 ) . Cell response . While heat will be lost from the wire not only by thermal conduction but also by gas flow ...
... cell , influence of fluctuations in flow rate may often be compensated by a prop- erly designed balancing cell ( Section 14-14 ) . Cell response . While heat will be lost from the wire not only by thermal conduction but also by gas flow ...
Sommario
THE SCIENCE OF INSTRUMENTATION | 1 |
ERRORS OF MEASUREMENT | 14 |
CHAPTER 3 | 37 |
Copyright | |
38 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Chemical Instrumentation: A Systematic Approach to Instrumental Analysis Howard A. Strobel Visualizzazione estratti - 1960 |
Parole e frasi comuni
absorbance absorption acid amplifier analysis analyzed angle anode applied atoms band beam Beer's law calibration calomel capacitance capacitor cathode cell Chem chemical circuit components concentration conductance constant coulometric curve detection detector determined device diffusion diode dispersion drop effect electrical electrode electrolysis electron tube emission end point energy error example filter frequency galvanometer glass grid incident input instrument intensity ionization ions layer liquid measurement mercury metal meter method mixture molecules obtained operation optical optical rotation output oxidized particles pH meter photometer phototube plate current platinum polarized polarographic potential potentiometer precision prism procedure quantitative radiation range reactance reaction reflection refractive index region resistance resistor result rotation sample sawtooth wave scattering schematic Section sensitivity shown in Fig signal slit solution solvent species spectra spectrophotometer spectrum standard substance techniques temperature thyratron tion titration transistor triode variable vibrational voltage wave wavelength