Chemical Instrumentation: A Systematic Approach to Instrumental AnalysisAddison-Wesley Publishing Company, 1960 - 653 pagine |
Dall'interno del libro
Risultati 1-3 di 65
Pagina 199
... output voltage is simply EQAT QP / L . = From Eq . ( 7-1 ) it appears that a high sensitivity calls for a small L. ( 7-1 ) The conflict in the two requirements can be resolved by making the receiver very small : both C and L will have ...
... output voltage is simply EQAT QP / L . = From Eq . ( 7-1 ) it appears that a high sensitivity calls for a small L. ( 7-1 ) The conflict in the two requirements can be resolved by making the receiver very small : both C and L will have ...
Pagina 336
... output FIG . 12-19 . Voltage amplifier with output arranged to isolate the amplified signal . Capacitor C blocks the d - c component and restricts it to the R1 arm . Only a - c appears at the output taps . Load resistance and plate ...
... output FIG . 12-19 . Voltage amplifier with output arranged to isolate the amplified signal . Capacitor C blocks the d - c component and restricts it to the R1 arm . Only a - c appears at the output taps . Load resistance and plate ...
Pagina 394
... Output . The usefulness of this circuit as a basic element in an electronic counter is associated with the nature of its output , which is obtained from load resistor RL2 . As discussed above , point D in the circuit of Fig . 13-7 is at ...
... Output . The usefulness of this circuit as a basic element in an electronic counter is associated with the nature of its output , which is obtained from load resistor RL2 . As discussed above , point D in the circuit of Fig . 13-7 is at ...
Sommario
THE SCIENCE OF INSTRUMENTATION | 1 |
ERRORS OF MEASUREMENT | 14 |
CHAPTER 3 | 37 |
Copyright | |
38 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Chemical Instrumentation: A Systematic Approach to Instrumental Analysis Howard A. Strobel Visualizzazione estratti - 1960 |
Parole e frasi comuni
absorbance absorption acid amplifier analysis analyzed angle anode applied atoms band beam Beer's law calibration calomel capacitance capacitor cathode cell Chem chemical circuit components concentration conductance constant coulometric curve detection detector determined device diffusion diode dispersion drop effect electrical electrode electrolysis electron tube emission end point energy error example filter frequency galvanometer glass grid incident input instrument intensity ionization ions layer liquid measurement mercury metal meter method mixture molecules obtained operation optical optical rotation output oxidized particles pH meter photometer phototube plate current platinum polarized polarographic potential potentiometer precision prism procedure quantitative radiation range reactance reaction reflection refractive index region resistance resistor result rotation sample sawtooth wave scattering schematic Section sensitivity shown in Fig signal slit solution solvent species spectra spectrophotometer spectrum standard substance techniques temperature thyratron tion titration transistor triode variable vibrational voltage wave wavelength