Chemical Instrumentation: A Systematic Approach to Instrumental AnalysisAddison-Wesley Publishing Company, 1960 - 653 pagine |
Dall'interno del libro
Risultati 1-3 di 55
Pagina 85
... slit . If a very large number of these are produced side by side , as in a wide gap , the new wavelets interfere so ... slit ( Fig . 4-19 ) , interference effects are appreciable . waves . The origin of a single wavelet at a slit is ...
... slit . If a very large number of these are produced side by side , as in a wide gap , the new wavelets interfere so ... slit ( Fig . 4-19 ) , interference effects are appreciable . waves . The origin of a single wavelet at a slit is ...
Pagina 116
... slit . Like all optical systems , a spectroscopic assembly produces images that are replicas of a source . It is vital to distinguish between the actual source ( an are ... Slit Slit ( a ) L2 Slit ( 116 [ CHAP . 5 EMISSION SPECTROSCOPY.
... slit . Like all optical systems , a spectroscopic assembly produces images that are replicas of a source . It is vital to distinguish between the actual source ( an are ... Slit Slit ( a ) L2 Slit ( 116 [ CHAP . 5 EMISSION SPECTROSCOPY.
Pagina 194
... slit Paraboloid Que mirror Slit width . A slit for a monochromator must come up to the same standards as that for a spectrograph ( Sections 5-5 , 5-6 ) . Its role in the monochromator is different , however . The slit , together with ...
... slit Paraboloid Que mirror Slit width . A slit for a monochromator must come up to the same standards as that for a spectrograph ( Sections 5-5 , 5-6 ) . Its role in the monochromator is different , however . The slit , together with ...
Sommario
THE SCIENCE OF INSTRUMENTATION | 1 |
ERRORS OF MEASUREMENT | 14 |
CHAPTER 3 | 37 |
Copyright | |
38 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Chemical Instrumentation: A Systematic Approach to Instrumental Analysis Howard A. Strobel Visualizzazione estratti - 1960 |
Parole e frasi comuni
absorbance absorption acid amplifier analysis analyzed angle anode applied atoms band beam Beer's law calibration calomel capacitance capacitor cathode cell Chem chemical circuit components concentration conductance constant coulometric curve detection detector determined device diffusion diode dispersion drop effect electrical electrode electrolysis electron tube emission end point energy error example filter frequency galvanometer glass grid incident input instrument intensity ionization ions layer liquid measurement mercury metal meter method mixture molecules obtained operation optical optical rotation output oxidized particles pH meter photometer phototube plate current platinum polarized polarographic potential potentiometer precision prism procedure quantitative radiation range reactance reaction reflection refractive index region resistance resistor result rotation sample sawtooth wave scattering schematic Section sensitivity shown in Fig signal slit solution solvent species spectra spectrophotometer spectrum standard substance techniques temperature thyratron tion titration transistor triode variable vibrational voltage wave wavelength