Principles of Instrumental AnalysisSaunders College Pub., 1992 - 700 pagine Introduction; operational amplifiers in chemical instrumentation;digital electronics, microprocessors,and computers; signal and noise; properties of electromagnetic radiation;instruments for optical spectroscopy;an introduction to molecular ultraviolet, visible and enar-infrared absorption spectroscopy;application of molecular ultraviolet,visible absorption spectroscopy;molecular fluorescence, phosphorescence and chemiluminescence; atomic spectroscopy based upon flame and electrothermal atomization;emission spectroscopy based upon plasma, arc and spark atomization;infrared absorption spectroscopy;raman spectroscopy;nuclear magnetic resonance spectroscopy;x-ray spectroscopy;analysis of surfaces with electron beams;radiochemical methods;mass spectrometry;an introduction to electroanalytical chemistry;potentiometric methods;coulometric methods; voltammetry; thermal methods;an introduction to chromatographic separation;gas chromatography;high-performance liquid chromatography;other separation methods;automated methods of analysis. |
Dall'interno del libro
Risultati 1-3 di 84
Pagina 8
... range Concentration LOL Useful range of an analytical method . limit of detector ; LOQ limit of quantitative measurement ; LOL limit of linear response . = = = measurements is generally taken as being equal to ten times the standard ...
... range Concentration LOL Useful range of an analytical method . limit of detector ; LOQ limit of quantitative measurement ; LOL limit of linear response . = = = measurements is generally taken as being equal to ten times the standard ...
Pagina 367
... range . As a consequence , an X - ray monochromator must be provided with at least two ( and preferably more ) interchangeable crystals . The useful wavelength range from a crystal is de- termined by its lattice spacing d and the ...
... range . As a consequence , an X - ray monochromator must be provided with at least two ( and preferably more ) interchangeable crystals . The useful wavelength range from a crystal is de- termined by its lattice spacing d and the ...
Pagina 457
... range from a few percent to as much as 20 % can be realized . The advantages of spark source mass spectrometry include its high sensitivity , its applicability to a wide range of sample matrices , the large linear dynamic range of the ...
... range from a few percent to as much as 20 % can be realized . The advantages of spark source mass spectrometry include its high sensitivity , its applicability to a wide range of sample matrices , the large linear dynamic range of the ...
Sommario
Overview | 1 |
Operational Amplifiers | 10 |
Digital Electronics Microprocessors | 29 |
Copyright | |
46 sezioni non visualizzate
Parole e frasi comuni
absorbance absorption activity addition amplifier Anal analysis analyte applications atomic band beam Calculate cause cell Chem chemical chromatography circuit column complex components compounds concentration constant containing curve described detector determination device difference discussion effect electrical electrons elements emission employed energy Equation example excited field filter fluorescence frequency function give given grating important increase infrared instruments intensity ions laser length less limited lines liquid magnetic mass measurements methods molecules monochromator noise Note observed obtained occurs operational optical output peak phase potential produced radiation Raman spectroscopy range ratio reaction reference region relative sample sensitivity separation shown in Figure shows signal slit solid solution solvent species spectra spectroscopy spectrum standard surface Table temperature transitions tube types typical usually vibrational voltage wave wavelength X-ray York