Analytical ChemistryHolt, Rinehart and Winston, 1979 - 685 pagine |
Dall'interno del libro
Risultati 1-3 di 24
Pagina 444
... detector or transducer that converts the radiant energy to a measurable signal ( usually electrical ) , and ( 5 ) a signal indicator . The block diagram in Figure 16-6 shows the usual arrangement of these components . The nature and the ...
... detector or transducer that converts the radiant energy to a measurable signal ( usually electrical ) , and ( 5 ) a signal indicator . The block diagram in Figure 16-6 shows the usual arrangement of these components . The nature and the ...
Pagina 486
... detector . For those atoms traveling away from the detector the wavelength is effectively increased by the well - known Doppler effect ; thus somewhat longer wavelengths are absorbed or emitted . The reverse is true of atoms moving ...
... detector . For those atoms traveling away from the detector the wavelength is effectively increased by the well - known Doppler effect ; thus somewhat longer wavelengths are absorbed or emitted . The reverse is true of atoms moving ...
Pagina 522
... detector , the thermistor has a negative temperature coefficient . In chromatographic applications a double detector is always employed , one element being placed in the gas stream ahead of the sample injection chamber and the other ...
... detector , the thermistor has a negative temperature coefficient . In chromatographic applications a double detector is always employed , one element being placed in the gas stream ahead of the sample injection chamber and the other ...
Sommario
Introduction | 1 |
A Review of Simple Equilibrium Constant | 24 |
The Evaluation of Analytical Data | 46 |
Copyright | |
49 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Parole e frasi comuni
absorbance absorption acid solution activity coefficient addition AgNO3 aliquot analysis analyte anode application approximately atoms base buffer buret calcium Calculate carbonate cathode cations cell cerium(IV chemical color column complex concen copper(II coulometric crucible determined dilute dissociation constant dissolved EDTA electrode potential electrolyte employed end point Equation equilibrium constant equivalence point equivalent weight example excess filter formal concentration formation formula weight glass H₂O H3O+ half-cell half-reaction hydrogen hydronium ion hydroxide indicator iodide iodine ion concentration iron(III liquid liter measurements mercury(II metal method molar NaOH oxalate oxidation particles permanganate pipet potassium precipitate prepared primary standard Procedure quantity radiation reaction reagent reduced sample silver chloride silver ion silver nitrate sodium solid solubility solution containing solvent species standard hydrogen electrode standard solution substance sulfuric acid Table temperature thiosulfate titration curve volume volumetric flask wavelength
Riferimenti a questo libro
Photocatalytic Purification and Treatment of Water and Air: Proceedings of ... David F. Ollis,Hussain Al-Ekabi Visualizzazione estratti - 1993 |
Biomedical TRANSDUCERS and INSTRUMENTS Tatsuo Togawa,Toshiyo Tamura,P. Ake Oberg Anteprima limitata - 1997 |