Analytical ChemistryHolt, Rinehart and Winston, 1979 - 685 pagine |
Dall'interno del libro
Risultati 1-3 di 86
Pagina 277
... electrode potential ( or more exactly , relative electrode potential ) is reserved exclusively for half - reactions written as reductions . There is no objection to the use of the term oxidation potential to connote an electrode process ...
... electrode potential ( or more exactly , relative electrode potential ) is reserved exclusively for half - reactions written as reductions . There is no objection to the use of the term oxidation potential to connote an electrode process ...
Pagina 281
... Electrode Potential , Eo . An examination of Equation 12-1 or Equation 12-2 reveals that the constant E ° is equal to the half - cell potential when the logarithmic term is zero . This condition occurs whenever the activity quotient is ...
... Electrode Potential , Eo . An examination of Equation 12-1 or Equation 12-2 reveals that the constant E ° is equal to the half - cell potential when the logarithmic term is zero . This condition occurs whenever the activity quotient is ...
Pagina 286
... potential of a silver electrode to the iodide ion concentration of a solution that is also saturated with silver iodide . When the iodide ion activity is unity , the potential is the sum of two constants ; this sum is the standard electrode ...
... potential of a silver electrode to the iodide ion concentration of a solution that is also saturated with silver iodide . When the iodide ion activity is unity , the potential is the sum of two constants ; this sum is the standard electrode ...
Sommario
Introduction | 1 |
A Review of Simple Equilibrium Constant | 24 |
The Evaluation of Analytical Data | 46 |
Copyright | |
49 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Parole e frasi comuni
absorbance absorption acid solution activity coefficient addition AgNO3 aliquot analysis analyte anode application approximately atoms base buffer buret calcium Calculate carbonate cathode cations cell cerium(IV chemical color column complex concen copper(II coulometric crucible determined dilute dissociation constant dissolved EDTA electrode potential electrolyte employed end point Equation equilibrium constant equivalence point equivalent weight example excess filter formal concentration formation formula weight glass H₂O H3O+ half-cell half-reaction hydrogen hydronium ion hydroxide indicator iodide iodine ion concentration iron(III liquid liter measurements mercury(II metal method molar NaOH oxalate oxidation particles permanganate pipet potassium precipitate prepared primary standard Procedure quantity radiation reaction reagent reduced sample silver chloride silver ion silver nitrate sodium solid solubility solution containing solvent species standard hydrogen electrode standard solution substance sulfuric acid Table temperature thiosulfate titration curve volume volumetric flask wavelength
Riferimenti a questo libro
Photocatalytic Purification and Treatment of Water and Air: Proceedings of ... David F. Ollis,Hussain Al-Ekabi Visualizzazione estratti - 1993 |
Biomedical TRANSDUCERS and INSTRUMENTS Tatsuo Togawa,Toshiyo Tamura,P. Ake Oberg Anteprima limitata - 1997 |