Analytical ChemistryHolt, Rinehart and Winston, 1979 - 685 pagine |
Dall'interno del libro
Risultati 1-3 di 42
Pagina 331
... iodine . The equivalent weight for the iodate is one - fourth of its formula weight because the final reaction product is iodine in the +1 state . When used in this manner , iodate is a less powerful oxidant than either permanganate or ...
... iodine . The equivalent weight for the iodate is one - fourth of its formula weight because the final reaction product is iodine in the +1 state . When used in this manner , iodate is a less powerful oxidant than either permanganate or ...
Pagina 332
... iodine is a great advantage . Disadvantages include the low stability of iodine solutions and the incompleteness of reactions between iodine and many reductants . Preparation of lodine Solutions . A saturated aqueous iodine solution is ...
... iodine is a great advantage . Disadvantages include the low stability of iodine solutions and the incompleteness of reactions between iodine and many reductants . Preparation of lodine Solutions . A saturated aqueous iodine solution is ...
Pagina 333
... iodine - iodide couple in acidic solutions because hydrogen ions do not participate in the half - reaction . Many of the substances that react with iodine , however , produce hydrogen ions as they are oxidized . The position of ...
... iodine - iodide couple in acidic solutions because hydrogen ions do not participate in the half - reaction . Many of the substances that react with iodine , however , produce hydrogen ions as they are oxidized . The position of ...
Sommario
Introduction | 1 |
A Review of Simple Equilibrium Constant | 24 |
The Evaluation of Analytical Data | 46 |
Copyright | |
49 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Parole e frasi comuni
absorbance absorption acid solution activity coefficient addition AgNO3 aliquot analysis analyte anode application approximately atoms base buffer buret calcium Calculate carbonate cathode cations cell cerium(IV chemical color column complex concen copper(II coulometric crucible determined dilute dissociation constant dissolved EDTA electrode potential electrolyte employed end point Equation equilibrium constant equivalence point equivalent weight example excess filter formal concentration formation formula weight glass H₂O H3O+ half-cell half-reaction hydrogen hydronium ion hydroxide indicator iodide iodine ion concentration iron(III liquid liter measurements mercury(II metal method molar NaOH oxalate oxidation particles permanganate pipet potassium precipitate prepared primary standard Procedure quantity radiation reaction reagent reduced sample silver chloride silver ion silver nitrate sodium solid solubility solution containing solvent species standard hydrogen electrode standard solution substance sulfuric acid Table temperature thiosulfate titration curve volume volumetric flask wavelength
Riferimenti a questo libro
Photocatalytic Purification and Treatment of Water and Air: Proceedings of ... David F. Ollis,Hussain Al-Ekabi Visualizzazione estratti - 1993 |
Biomedical TRANSDUCERS and INSTRUMENTS Tatsuo Togawa,Toshiyo Tamura,P. Ake Oberg Anteprima limitata - 1997 |