Analytical ChemistryHolt, Rinehart and Winston, 1979 - 685 pagine |
Dall'interno del libro
Risultati 1-3 di 38
Pagina 205
... limited than that for a strong acid . For example , bromocresol green is totally unsuited for titration of 0.1000 - F acetic acid ; nor would bromo- thymol blue be satisfactory because its full color change would occur over a range ...
... limited than that for a strong acid . For example , bromocresol green is totally unsuited for titration of 0.1000 - F acetic acid ; nor would bromo- thymol blue be satisfactory because its full color change would occur over a range ...
Pagina 232
... limited , the reagent is ordinarily dissolved in ethanol prior to dilution and titration . Potassium hydrogen iodate , KH ( IO3 ) 2 , is an excellent primary standard with a high equivalent weight . It is also a strong acid ; as a ...
... limited , the reagent is ordinarily dissolved in ethanol prior to dilution and titration . Potassium hydrogen iodate , KH ( IO3 ) 2 , is an excellent primary standard with a high equivalent weight . It is also a strong acid ; as a ...
Pagina 448
... limited by the sensitivity of the detector . For fixed slit widths the effective band width of a prism mono- chromator increases continuously as the wavelength of radiation increases because the refractive index of any prism material ...
... limited by the sensitivity of the detector . For fixed slit widths the effective band width of a prism mono- chromator increases continuously as the wavelength of radiation increases because the refractive index of any prism material ...
Sommario
Introduction | 1 |
A Review of Simple Equilibrium Constant | 24 |
The Evaluation of Analytical Data | 46 |
Copyright | |
49 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Parole e frasi comuni
absorbance absorption acid solution activity coefficient addition AgNO3 aliquot analysis analyte anode application approximately atoms base buffer buret calcium Calculate carbonate cathode cations cell cerium(IV chemical color column complex concen copper(II coulometric crucible determined dilute dissociation constant dissolved EDTA electrode potential electrolyte employed end point Equation equilibrium constant equivalence point equivalent weight example excess filter formal concentration formation formula weight glass H₂O H3O+ half-cell half-reaction hydrogen hydronium ion hydroxide indicator iodide iodine ion concentration iron(III liquid liter measurements mercury(II metal method molar NaOH oxalate oxidation particles permanganate pipet potassium precipitate prepared primary standard Procedure quantity radiation reaction reagent reduced sample silver chloride silver ion silver nitrate sodium solid solubility solution containing solvent species standard hydrogen electrode standard solution substance sulfuric acid Table temperature thiosulfate titration curve volume volumetric flask wavelength
Riferimenti a questo libro
Photocatalytic Purification and Treatment of Water and Air: Proceedings of ... David F. Ollis,Hussain Al-Ekabi Visualizzazione estratti - 1993 |
Biomedical TRANSDUCERS and INSTRUMENTS Tatsuo Togawa,Toshiyo Tamura,P. Ake Oberg Anteprima limitata - 1997 |