Analytical ChemistryHolt, Rinehart and Winston, 1979 - 685 pagine |
Dall'interno del libro
Risultati 1-3 di 25
Pagina 57
... pipet . The data in Table 4-1 are typical of those that might be obtained by an experienced and competent worker who ... pipet , the mercury level in the thermometer , and the position of an indicator with respect to a scale in the ...
... pipet . The data in Table 4-1 are typical of those that might be obtained by an experienced and competent worker who ... pipet , the mercury level in the thermometer , and the position of an indicator with respect to a scale in the ...
Pagina 558
... pipet . This drop is blown from some pipets but not from others . Table 19-3 and Figure 19-15 summarize the several varieties most likely to be encountered in an analytical laboratory . Burets . Burets , like measuring pipets , enable ...
... pipet . This drop is blown from some pipets but not from others . Table 19-3 and Figure 19-15 summarize the several varieties most likely to be encountered in an analytical laboratory . Burets . Burets , like measuring pipets , enable ...
Pagina 568
... Pipet . The calibration of a flask relative to a pipet provides an excellent method for partitioning a sample into aliquots . The following directions pertain specifically to a 50 - ml pipet and a 500 - ml flask ; other combinations are ...
... Pipet . The calibration of a flask relative to a pipet provides an excellent method for partitioning a sample into aliquots . The following directions pertain specifically to a 50 - ml pipet and a 500 - ml flask ; other combinations are ...
Sommario
Introduction | 1 |
A Review of Simple Equilibrium Constant | 24 |
The Evaluation of Analytical Data | 46 |
Copyright | |
49 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Parole e frasi comuni
absorbance absorption acid solution activity coefficient addition AgNO3 aliquot analysis analyte anode application approximately atoms base buffer buret calcium Calculate carbonate cathode cations cell cerium(IV chemical color column complex concen copper(II coulometric crucible determined dilute dissociation constant dissolved EDTA electrode potential electrolyte employed end point Equation equilibrium constant equivalence point equivalent weight example excess filter formal concentration formation formula weight glass H₂O H3O+ half-cell half-reaction hydrogen hydronium ion hydroxide indicator iodide iodine ion concentration iron(III liquid liter measurements mercury(II metal method molar NaOH oxalate oxidation particles permanganate pipet potassium precipitate prepared primary standard Procedure quantity radiation reaction reagent reduced sample silver chloride silver ion silver nitrate sodium solid solubility solution containing solvent species standard hydrogen electrode standard solution substance sulfuric acid Table temperature thiosulfate titration curve volume volumetric flask wavelength
Riferimenti a questo libro
Photocatalytic Purification and Treatment of Water and Air: Proceedings of ... David F. Ollis,Hussain Al-Ekabi Visualizzazione estratti - 1993 |
Biomedical TRANSDUCERS and INSTRUMENTS Tatsuo Togawa,Toshiyo Tamura,P. Ake Oberg Anteprima limitata - 1997 |