Analytical ChemistryHolt, Rinehart and Winston, 1979 - 685 pagine |
Dall'interno del libro
Risultati 1-3 di 85
Pagina 9
... quantity contains slightly less than 1 mole of the species H2O because of the existence of H3O * , OH ̄ , H4O2 , and such other species as may be present . Laboratory quantities are frequently more conveniently expressed in terms of ...
... quantity contains slightly less than 1 mole of the species H2O because of the existence of H3O * , OH ̄ , H4O2 , and such other species as may be present . Laboratory quantities are frequently more conveniently expressed in terms of ...
Pagina 62
... Quantity measured , x 0+ Deviation from mean , ( x -μ ) -30 20 0 +20 +30 Methods 1 and 2 yield identical curves with ... quantity by two methods . Method 1 is more reliable ; thus σ is smaller . Note the three types of abscissa ...
... Quantity measured , x 0+ Deviation from mean , ( x -μ ) -30 20 0 +20 +30 Methods 1 and 2 yield identical curves with ... quantity by two methods . Method 1 is more reliable ; thus σ is smaller . Note the three types of abscissa ...
Pagina 294
... quantities used to prepare the cell . The silver ion concentration could be calculated from the potential of the ... quantity called the formal potential in place of the standard electrode potential . The formal potential of a system ...
... quantities used to prepare the cell . The silver ion concentration could be calculated from the potential of the ... quantity called the formal potential in place of the standard electrode potential . The formal potential of a system ...
Sommario
Introduction | 1 |
A Review of Simple Equilibrium Constant | 24 |
The Evaluation of Analytical Data | 46 |
Copyright | |
49 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Parole e frasi comuni
absorbance absorption acid solution activity coefficient addition AgNO3 aliquot analysis analyte anode application approximately atoms base buffer buret calcium Calculate carbonate cathode cations cell cerium(IV chemical color column complex concen copper(II coulometric crucible determined dilute dissociation constant dissolved EDTA electrode potential electrolyte employed end point Equation equilibrium constant equivalence point equivalent weight example excess filter formal concentration formation formula weight glass H₂O H3O+ half-cell half-reaction hydrogen hydronium ion hydroxide indicator iodide iodine ion concentration iron(III liquid liter measurements mercury(II metal method molar NaOH oxalate oxidation particles permanganate pipet potassium precipitate prepared primary standard Procedure quantity radiation reaction reagent reduced sample silver chloride silver ion silver nitrate sodium solid solubility solution containing solvent species standard hydrogen electrode standard solution substance sulfuric acid Table temperature thiosulfate titration curve volume volumetric flask wavelength
Riferimenti a questo libro
Photocatalytic Purification and Treatment of Water and Air: Proceedings of ... David F. Ollis,Hussain Al-Ekabi Visualizzazione estratti - 1993 |
Biomedical TRANSDUCERS and INSTRUMENTS Tatsuo Togawa,Toshiyo Tamura,P. Ake Oberg Anteprima limitata - 1997 |