Analytical Chemistry |
Dall'interno del libro
Risultati 1-3 di 75
Pagina 233
Typical Applications of Neutralization Titrations The most obvious application of
neutralization methods is to determine the innumerable inorganic , organic , and
biological species that possess inherent acidic or basic properties . Equally ...
Typical Applications of Neutralization Titrations The most obvious application of
neutralization methods is to determine the innumerable inorganic , organic , and
biological species that possess inherent acidic or basic properties . Equally ...
Pagina 423
A typical apparatus is shown in Figure 15 - 13 . Polarographic waves , similar in
appearance to those observed with the dropping mercury electrode , can be
obtained with the rotating platinum electrode . Here , however , the reactive
species is ...
A typical apparatus is shown in Figure 15 - 13 . Polarographic waves , similar in
appearance to those observed with the dropping mercury electrode , can be
obtained with the rotating platinum electrode . Here , however , the reactive
species is ...
Pagina 452
Currents on the order of 10 to 100 u A are typical . Photovoltaic cells are used
primarily for the detection and measurement of radiation in the visible region .
The typical cell has a maximum sensitivity at about 550 nm , and the response
falls off ...
Currents on the order of 10 to 100 u A are typical . Photovoltaic cells are used
primarily for the detection and measurement of radiation in the visible region .
The typical cell has a maximum sensitivity at about 550 nm , and the response
falls off ...
Cosa dicono le persone - Scrivi una recensione
Nessuna recensione trovata nei soliti posti.
Sommario
Introduction | 1 |
A Review of Simple Equilibrium Constant | 24 |
The Evaluation of Analytical Data | 46 |
Copyright | |
55 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Parole e frasi comuni
absorbance absorption acid activity added addition agent analysis analyte application atomic balance base beam becomes buffer Calculate carbonate cations cause cell chemical chloride chromatography color column complex components concentration constant containing curve depends described determined difference dilute direct dissociation dissolved EDTA effect electrode elements employed end point Equation equilibrium equivalence point error example excess exist expression Figure filtered formation give given glass hydrogen important increases indicator involves iodine less limited liquid mean measurement metal method mixture NaOH needed Neutralization Note obtained occurs organic oxidation particles phase potassium potential precipitate prepared presence quantity radiation range reaction reagent reduced reference region relative sample separation shown silver sodium solid solubility solution solution containing species standard substance surface Table temperature titration typical volume volumetric wavelength weight
Riferimenti a questo libro
Photocatalytic Purification and Treatment of Water and Air: Proceedings of ... David F. Ollis,Hussain Al-Ekabi Visualizzazione frammento - 1993 |
Biomedical TRANSDUCERS and INSTRUMENTS Tatsuo Togawa,Toshiyo Tamura,P. Ake Oberg Anteprima limitata - 1997 |