Analytical ChemistryHolt, Rinehart and Winston, 1979 - 685 pagine |
Dall'interno del libro
Risultati 1-3 di 81
Pagina 556
... volume occupied by a given mass of liquid varies with temperature . So also does the volume of the container that holds the liquid . The accurate measurement of volume may require taking both of these temperature effects into account ...
... volume occupied by a given mass of liquid varies with temperature . So also does the volume of the container that holds the liquid . The accurate measurement of volume may require taking both of these temperature effects into account ...
Pagina 565
... volume occupied by a given mass of liquid varies with temperature . Second , the volume of the apparatus itself is variable , owing to the tendency of the glass to expand or contract with changes in temperature . We noted earlier ( p ...
... volume occupied by a given mass of liquid varies with temperature . Second , the volume of the apparatus itself is variable , owing to the tendency of the glass to expand or contract with changes in temperature . We noted earlier ( p ...
Pagina 567
... volumes . PROCEDURE Calibration of a Volumetric Pipet . Determine the empty weight of a stoppered receiver to the nearest milligram . Transfer a volume of water to the receiver with the pipet ( p . 560 ) , weigh the receiver and ...
... volumes . PROCEDURE Calibration of a Volumetric Pipet . Determine the empty weight of a stoppered receiver to the nearest milligram . Transfer a volume of water to the receiver with the pipet ( p . 560 ) , weigh the receiver and ...
Sommario
Introduction | 1 |
A Review of Simple Equilibrium Constant | 24 |
The Evaluation of Analytical Data | 58 |
Copyright | |
53 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Parole e frasi comuni
absorbance absorption acid solution activity coefficient addition AgNO3 aliquot analysis analyte anode application aqueous base buffer cadmium calcium carbonate cathode cation cell cerium(IV chemical color complex concen coulometric determined dilute dissociation constant dissolved EDTA electrode potential electrolyte employed end point Equation equilibrium constant equivalence point equivalent weight error example excess Fe² Fe³ filter flask formal concentration formation formula weight glass gravimetric H₂O H3O+ half-cell half-reaction hydrogen ion hydroxide iodide iodine ionic strength iron(II K₁ liquid measurement membrane mercury(II metal method molar NaOH oxalate oxidation oxidation-reduction particles permanganate polarographic potassium precipitate primary standard quantity radiation react reactants reaction reagent reduced sample saturated silver chloride silver ion silver nitrate sodium solid solubility solution containing species standard electrode potential standard hydrogen electrode standard solution substance sulfuric acid Table temperature thiosulfate titration curves volume volumetric wavelength zinc
Riferimenti a questo libro
Photocatalytic Purification and Treatment of Water and Air: Proceedings of ... David F. Ollis,Hussain Al-Ekabi Visualizzazione estratti - 1993 |
Biomedical TRANSDUCERS and INSTRUMENTS Tatsuo Togawa,Toshiyo Tamura,P. Ake Oberg Anteprima limitata - 1997 |