Chemical Instrumentation: A Systematic ApproachWiley, 22 feb 1989 - 1248 pagine The Third Edition of this established work on chemical instrumentation has been completely rewritten and updated to account for the advances made since the Second Edition came out in 1973. More main methods of measurement are presented, and there is extended coverage of chromatography and electrochemistry. Most of the material is new--including coverage of microprocessors and microcomputers, statistical control of measurement quality, quantification and extraction of information, x-ray fluorescence spectrometry, surface spectrometric techniques, and chromatography and HPLC. The quality and range of the worked examples have been improved, and there are end-of-chapter exercises. |
Dall'interno del libro
Risultati 1-3 di 78
Pagina 354
... method for determination of chromium that has just been published is to be tested . To establish its reliability , it is compared with a method long in use in the laboratory by a two - group experiment . Both methods are applied to a ...
... method for determination of chromium that has just been published is to be tested . To establish its reliability , it is compared with a method long in use in the laboratory by a two - group experiment . Both methods are applied to a ...
Pagina 355
... methods do not yield statistically similar results , and it is probable that the new method has systematic error . Limitations of the t - Test . Basically , the t - test applies to data that are normally distributed . In the event data ...
... methods do not yield statistically similar results , and it is probable that the new method has systematic error . Limitations of the t - Test . Basically , the t - test applies to data that are normally distributed . In the event data ...
Pagina 356
... method with a new or test method . It is assumed that the reference method is well established and yields both precise and accurate results . Each point represents both methods : its x coordinate is the value obtained for the analyte by ...
... method with a new or test method . It is assumed that the reference method is well established and yields both precise and accurate results . Each point represents both methods : its x coordinate is the value obtained for the analyte by ...
Sommario
Measurement and Instrumentation | 1 |
BASIC ELECTRONICS | 21 |
Analog Electrical and Electronic Modules | 57 |
Copyright | |
31 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Chemical Instrumentation: A Systematic Approach Howard A. Strobel,William R. Heineman Visualizzazione estratti - 1989 |
Parole e frasi comuni
absorbance absorption amplifier amplitude analysis analyte analytical signal angle anode atoms beam Beer's law calibration capacitor cathode cell Chem chemical chromatographic circuit column components concentration constant curve detection detector determined device diode dispersion electrochemical cell electron elements elution emission energy equation error example excitation filter flame fluorescence frequency gas chromatograph grating incident input instrument intensity ionization laser light limits mass mass spectrometer measurements method mobile phase modules molar absorptivity molecular molecules monochromator noise obtained op-amp operation operational amplifier optical output particles peak photomultiplier photon plate polarized potential precision prism pulse radiation Raman range ratio rays reflection refractive index resistor resolution result sample scanning scattering Section shown in Fig signal slit solution species spectral spectrometer spectrophotometer spectroscopy spectrum standard stationary phase surface techniques temperature tube V₁ vibrational voltage wave wavelength wavenumber width X-ray