Chemical Instrumentation: A Systematic ApproachWiley, 22 feb 1989 - 1210 pagine The Third Edition of this established work on chemical instrumentation has been completely rewritten and updated to account for the advances made since the Second Edition came out in 1973. More main methods of measurement are presented, and there is extended coverage of chromatography and electrochemistry. Most of the material is new--including coverage of microprocessors and microcomputers, statistical control of measurement quality, quantification and extraction of information, x-ray fluorescence spectrometry, surface spectrometric techniques, and chromatography and HPLC. The quality and range of the worked examples have been improved, and there are end-of-chapter exercises. |
Dall'interno del libro
Risultati 1-3 di 72
Pagina 1055
... techniques discussed in Chapter 28 are termed passive techniques since they are based on the measurement of a cell po- tential that is simply a response to the activity of an analyte in solution . The basic concept of applying a ...
... techniques discussed in Chapter 28 are termed passive techniques since they are based on the measurement of a cell po- tential that is simply a response to the activity of an analyte in solution . The basic concept of applying a ...
Pagina 1056
... techniques are quite varied , they all share the common basis of applying E and measuring i or a parameter derived from i such as charge Q. The most useful of these techniques for analysis are explained and illustrated in this chapter ...
... techniques are quite varied , they all share the common basis of applying E and measuring i or a parameter derived from i such as charge Q. The most useful of these techniques for analysis are explained and illustrated in this chapter ...
Pagina 1112
... TECHNIQUES William R. Heineman 30.1 INTRODUCTION Stationary solution voltammetric techniques are implemented in quiescent solution so that diffusion is the only means of mass transport of electroactive species to the electrode surface ...
... TECHNIQUES William R. Heineman 30.1 INTRODUCTION Stationary solution voltammetric techniques are implemented in quiescent solution so that diffusion is the only means of mass transport of electroactive species to the electrode surface ...
Sommario
Measurement and Instrumentation | 1 |
BASIC ELECTRONICS | 21 |
Analog Electrical and Electronic Modules | 57 |
Copyright | |
31 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Chemical Instrumentation: A Systematic Approach Howard A. Strobel,William R. Heineman Visualizzazione estratti - 1989 |
Parole e frasi comuni
absorbance absorption amplifier amplitude analysis analyte analytical signal angle anode atoms beam Beer's law calibration capacitor cathode cell Chem chemical chromatographic circuit column components concentration constant curve detection detector determined device diode dispersion electrochemical cell electron elements elution emission energy equation error example excitation filter flame fluorescence frequency gas chromatograph grating incident input instrument intensity ionization laser light limits mass mass spectrometer measurements method mobile phase modules molar absorptivity molecular molecules monochromator noise obtained op-amp operation operational amplifier optical output particles peak photomultiplier photon plate polarized potential precision prism pulse radiation Raman range ratio rays reflection refractive index resistor resolution result sample scanning scattering Section shown in Fig signal slit solution species spectral spectrometer spectrophotometer spectroscopy spectrum standard stationary phase surface techniques temperature tube V₁ vibrational voltage wave wavelength wavenumber width X-ray