Analytical ChemistryXerox College Pub., 1971 - 508 pagine |
Dall'interno del libro
Risultati 1-3 di 77
Pagina 262
Gary D. Christian. Another widely used electrode of this type is the calomel electrode , Hg , Hg2Cl2 ( s ) / Cl- . This will be described in more detail when we talk about reference electrodes . 3. ELECTRODE OF THE THIRD KIND The general ...
Gary D. Christian. Another widely used electrode of this type is the calomel electrode , Hg , Hg2Cl2 ( s ) / Cl- . This will be described in more detail when we talk about reference electrodes . 3. ELECTRODE OF THE THIRD KIND The general ...
Pagina 266
... electrode is designated the indicator electrode . Obviously , then , the potential of the other electrode should be constant , and its potential should not be dependent on the properties of the solution being tested . This electrode is ...
... electrode is designated the indicator electrode . Obviously , then , the potential of the other electrode should be constant , and its potential should not be dependent on the properties of the solution being tested . This electrode is ...
Pagina 281
... electrodes is not known . Undoubt- edly , some have mechanisms similar to that of the glass electrode . The selectivity of cation electrodes is due to the presence of anionic sites that show affinity toward certain cations , while the ...
... electrodes is not known . Undoubt- edly , some have mechanisms similar to that of the glass electrode . The selectivity of cation electrodes is due to the presence of anionic sites that show affinity toward certain cations , while the ...
Sommario
Introduction | 3 |
Basic Tools of Analytical Chemistry | 15 |
Experiment | 16 |
Copyright | |
29 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Parole e frasi comuni
absorbance absorption acetic acid solution activity activity coefficient added agent alkaline amount analysis analytical anion atomic beaker beta particles blood buffer buret calcium Calculate calibration carbon cathode cell chelate chloride chromatography color column complex compounds concentration constant containing coulometric crucible decrease detector determined dilute dissolved distilled water EDTA electrode electrolyte eluted end point enzyme Equation equivalence point Erlenmeyer flask error example extraction Figure filter flame flask glass glucose half-reaction hydrochloric acid hydrogen hydroxide indicator instrument iodide ion-selective electrodes ionization measured mercury metal mixture mmoles molecule NaOH Nernst equation nitrogen oxidizing oxidizing agent particles percent perchloric acid pipet potassium potential precipitate prepared procedure protein reaction reagent redox reduced salt sample separation serum sodium soluble solvent substance sulfuric sulfuric acid temperature titration titration curve tube unknown volume volumetric volumetric flask wavelength weight zero