Analytical ChemistryXerox College Pub., 1971 - 508 pagine |
Dall'interno del libro
Risultati 1-3 di 83
Pagina 44
... Example : Left Right 1.9 17.4 2.4 17.0 3.0 2 ) 34.4 3 ) 7.3 2.43 17.2 2.43 2 ) 19.63 9.82 For most purposes , zero points and rest points should be rounded off to one deci- mal place , or 9.8 in the above example . Perform this ...
... Example : Left Right 1.9 17.4 2.4 17.0 3.0 2 ) 34.4 3 ) 7.3 2.43 17.2 2.43 2 ) 19.63 9.82 For most purposes , zero points and rest points should be rounded off to one deci- mal place , or 9.8 in the above example . Perform this ...
Pagina 391
... example , the enzyme succinic dehydrogenase will specifically catalyze the dehydrogenation of succinic acid to form fumaric acid . But other compounds similar to succinic acid will competitively inhibit the reaction . Examples are other ...
... example , the enzyme succinic dehydrogenase will specifically catalyze the dehydrogenation of succinic acid to form fumaric acid . But other compounds similar to succinic acid will competitively inhibit the reaction . Examples are other ...
Pagina 495
... example . Note that in the example , the sum of the two exponents is equal to the original exponent ( -0.326 ) . Another example is : log N = -4.723 N = 10-4.723 = 100.277 X 10-5 = 1.89 X 10-5 = 0.0000189 . A.4 Using Logarithm Tables ...
... example . Note that in the example , the sum of the two exponents is equal to the original exponent ( -0.326 ) . Another example is : log N = -4.723 N = 10-4.723 = 100.277 X 10-5 = 1.89 X 10-5 = 0.0000189 . A.4 Using Logarithm Tables ...
Sommario
Introduction | 3 |
Basic Tools of Analytical Chemistry | 15 |
Experiment | 16 |
Copyright | |
29 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Parole e frasi comuni
absorbance absorption acetic acid solution activity activity coefficient added agent alkaline amount analysis analytical anion atomic beaker beta particles blood buffer buret calcium Calculate calibration carbon cathode cell chelate chloride chromatography color column complex compounds concentration constant containing coulometric crucible decrease detector determined dilute dissolved distilled water EDTA electrode electrolyte eluted end point enzyme Equation equivalence point Erlenmeyer flask error example extraction Figure filter flame flask glass glucose half-reaction hydrochloric acid hydrogen hydroxide indicator instrument iodide ion-selective electrodes ionization measured mercury metal mixture mmoles molecule NaOH Nernst equation nitrogen oxidizing oxidizing agent particles percent perchloric acid pipet potassium potential precipitate prepared procedure protein reaction reagent redox reduced salt sample separation serum sodium soluble solvent substance sulfuric sulfuric acid temperature titration titration curve tube unknown volume volumetric volumetric flask wavelength weight zero