Analytical ChemistryXerox College Pub., 1971 - 508 pagine |
Dall'interno del libro
Risultati 1-3 di 7
Pagina 20
... F , beam arrest ; G , pan arrest ; H , rider control . ( Courtesy of Arthur H. Thomas Company . ) The knife edges and plates are made of agate , a hard and brittle material . The knife is ground to a very sharp edge , which results in a ...
... F , beam arrest ; G , pan arrest ; H , rider control . ( Courtesy of Arthur H. Thomas Company . ) The knife edges and plates are made of agate , a hard and brittle material . The knife is ground to a very sharp edge , which results in a ...
Pagina 91
... weight of AgCl and AgBr in the original mixture . 12. Calculate the ... weight of sample would have to be taken so that the weight of precipi- tate is equal ... F. Holmes , " Organic Reagents in Inorganic Analysis , " ibid . , Chap- ter ...
... weight of AgCl and AgBr in the original mixture . 12. Calculate the ... weight of sample would have to be taken so that the weight of precipi- tate is equal ... F. Holmes , " Organic Reagents in Inorganic Analysis , " ibid . , Chap- ter ...
Pagina 116
... ( f ) Organic ions of high molecular weight and anionic complexes of metal ions exhibit unusually high selectivities . Some typical orders of affinity for selected groups of ions are : Cs + < Ag + TI + ( after the alkali metals in b above ) ...
... ( f ) Organic ions of high molecular weight and anionic complexes of metal ions exhibit unusually high selectivities . Some typical orders of affinity for selected groups of ions are : Cs + < Ag + TI + ( after the alkali metals in b above ) ...
Sommario
Introduction | 3 |
Basic Tools of Analytical Chemistry | 15 |
Experiment | 16 |
Copyright | |
29 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Parole e frasi comuni
absorbance absorption acetic acid solution activity activity coefficient added agent alkaline amount analysis analytical anion atomic beaker beta particles blood buffer buret calcium Calculate calibration carbon cathode cell chelate chloride chromatography color column complex compounds concentration constant containing coulometric crucible decrease detector determined dilute dissolved distilled water EDTA electrode electrolyte eluted end point enzyme Equation equivalence point Erlenmeyer flask error example extraction Figure filter flame flask glass glucose half-reaction hydrochloric acid hydrogen hydroxide indicator instrument iodide ion-selective electrodes ionization measured mercury metal mixture mmoles molecule NaOH Nernst equation nitrogen oxidizing oxidizing agent particles percent perchloric acid pipet potassium potential precipitate prepared procedure protein reaction reagent redox reduced salt sample separation serum sodium soluble solvent substance sulfuric sulfuric acid temperature titration titration curve tube unknown volume volumetric volumetric flask wavelength weight zero