... serum samples . Read the potential of an undiluted serum sample to the nearest 0.1 mV . Measurements should be made at the same tem- perature as the standards . 12 Make duplicate readings and from the calibration A synthetic aqueous " serum ...
... serum samples . Read the potential of an undiluted serum sample to the nearest 0.1 mV . Measurements should be made at the same tem- perature as the standards . 12 Make duplicate readings and from the calibration A synthetic aqueous " serum ...
Pagina 371
... Serum . Calcium in serum or an " artificial serum " as described in Ex- periment 19.1 is determined by diluting 1:20 with 1 % SrCl2 solution.1 Sodium and potassium equal to that in the sample are added to the standards . Add 0.5 ml of ...
... Serum . Calcium in serum or an " artificial serum " as described in Ex- periment 19.1 is determined by diluting 1:20 with 1 % SrCl2 solution.1 Sodium and potassium equal to that in the sample are added to the standards . Add 0.5 ml of ...
Pagina 472
... serum or plasma . If it is the concentration in the serum or plasma that is clinically significant , then hemolysis would give erroneously high serum or plasma results , as in the case of potassium , iron , magnesium , zinc , urea ...
... serum or plasma . If it is the concentration in the serum or plasma that is clinically significant , then hemolysis would give erroneously high serum or plasma results , as in the case of potassium , iron , magnesium , zinc , urea ...
Sommario
Introduction | 3 |
Basic Tools of Analytical Chemistry | 15 |
Experiment | 16 |
Copyright | |
30 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Parole e frasi comuni
absorbance absorption acetic acid solution activity activity coefficient added agent alkaline amount analysis analytical anion atomic beaker beta particles blood buffer buret calcium Calculate calibration carbon cathode cell chelate chloride chromatography color column complex compounds concentration constant containing coulometric crucible decrease detector determined dilute dissolved distilled water EDTA electrode electrolyte eluted end point enzyme Equation equivalence point Erlenmeyer flask error example extraction Figure filter flame flask glass glucose half-reaction hydrochloric acid hydrogen hydroxide indicator instrument iodide ion-selective electrodes ionization laboratory measured mercury metal mixture mmoles molecule NaOH nitrogen oxidizing oxidizing agent particles percent perchloric acid pipet potassium potential precipitate prepared procedure protein reaction reagent redox reduced salt sample separation serum sodium soluble solvent substance sulfate sulfuric sulfuric acid temperature titration titration curve tube unknown volume volumetric volumetric flask wavelength weight zero