Chemical Instrumentation: A Systematic Approach to Instrumental AnalysisAddison-Wesley Publishing Company, 1960 - 653 pagine |
Dall'interno del libro
Risultati 1-3 di 57
Pagina 83
... band transmitted by a filter is centered at A , other transmission bands will appear at the wavelengths X / 2 , X / 3 , λ / 4 , ... EXAMPLE . The thickness of the dielectric layer required for a first - order band at 500 mu is desired ...
... band transmitted by a filter is centered at A , other transmission bands will appear at the wavelengths X / 2 , X / 3 , λ / 4 , ... EXAMPLE . The thickness of the dielectric layer required for a first - order band at 500 mu is desired ...
Pagina 192
... band at 700 mμ has been blocked . ) B , Multilayer interference filter with " primary " band at 595 mp . C , Corning 3389 sharp cutoff filter . D , Corning narrow bandpass filter made by combining filters 3389 and 5113 . E , Corning ...
... band at 700 mμ has been blocked . ) B , Multilayer interference filter with " primary " band at 595 mp . C , Corning 3389 sharp cutoff filter . D , Corning narrow bandpass filter made by combining filters 3389 and 5113 . E , Corning ...
Pagina 269
... bands . These regions of continuous levels may be widely separated or may overlap . In metals , the lowest - lying band , the s - region , is considered to overlap the next lowest band , the p - region . Note the adoption of the letters ...
... bands . These regions of continuous levels may be widely separated or may overlap . In metals , the lowest - lying band , the s - region , is considered to overlap the next lowest band , the p - region . Note the adoption of the letters ...
Sommario
THE SCIENCE OF INSTRUMENTATION | 1 |
ERRORS OF MEASUREMENT | 14 |
CHAPTER 3 | 34 |
Copyright | |
39 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Chemical Instrumentation: A Systematic Approach to Instrumental Analysis Howard A. Strobel Visualizzazione estratti - 1960 |
Parole e frasi comuni
absorbance absorption acid amplifier analysis analyzed angle anode applied atoms band beam Beer's law calibration calomel capacitance capacitor cathode cell Chem chemical circuit components concentration conductance constant coulometric curve detection detector determined device diffusion diode dispersion drop effect electrical electrode electrolysis emission end point energy error example filter frequency galvanometer gas chromatography glass grid incident input instrument intensity ionization ions layer liquid measurement mercury metal meter method mixture molecules obtained operation optical optical rotation output oxidized particles pH meter photometer phototube plate current platinum polarized polarographic potential potentiometer precision prism procedure quantitative radiation range reaction reflection refractive index region resistance resistor result rotation sample sawtooth wave scattering schematic Section sensitivity shown in Fig signal slit solution solvent species spectra spectrophotometer spectrum standard substance techniques temperature thyratron tion titration transistor triode variable vibrational voltage wave wavelength