Chemical Instrumentation: A Systematic Approach to Instrumental AnalysisAddison-Wesley Publishing Company, 1960 - 653 pagine |
Dall'interno del libro
Risultati 1-3 di 31
Pagina 316
... diode shown in Fig . 12-2 . Let the electrodes be plane and parallel , and the electrostatic field between them be uniform . The time of flight may be found by substituting F from Eq . ( 12-1 ) into the ... DIODE 12-3 Diode characteristics.
... diode shown in Fig . 12-2 . Let the electrodes be plane and parallel , and the electrostatic field between them be uniform . The time of flight may be found by substituting F from Eq . ( 12-1 ) into the ... DIODE 12-3 Diode characteristics.
Pagina 367
... diode ( see Fig . 12-8 ) . As a result of these factors , the circuit is well adapted to semiconductor diodes . Naturally , filters must follow this rectifier stage if smooth d - c ... diode may be used as a 12-20 ] 367 RECTIFIERS AND DIODES.
... diode ( see Fig . 12-8 ) . As a result of these factors , the circuit is well adapted to semiconductor diodes . Naturally , filters must follow this rectifier stage if smooth d - c ... diode may be used as a 12-20 ] 367 RECTIFIERS AND DIODES.
Pagina 394
... diode with a positive plate , diode 2. The result is a nega- tive signal to the grid of triode 2 , and the shift of the oscillator to its other operating state is set in action . While triode 1 is conducting , diode 1 will be biased to ...
... diode with a positive plate , diode 2. The result is a nega- tive signal to the grid of triode 2 , and the shift of the oscillator to its other operating state is set in action . While triode 1 is conducting , diode 1 will be biased to ...
Sommario
THE SCIENCE OF INSTRUMENTATION | 1 |
ERRORS OF MEASUREMENT | 14 |
CHAPTER 3 | 34 |
Copyright | |
39 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Chemical Instrumentation: A Systematic Approach to Instrumental Analysis Howard A. Strobel Visualizzazione estratti - 1960 |
Parole e frasi comuni
absorbance absorption acid amplifier analysis analyzed angle anode applied atoms band beam Beer's law calibration calomel capacitance capacitor cathode cell Chem chemical circuit components concentration conductance constant coulometric curve detection detector determined device diffusion diode dispersion drop effect electrical electrode electrolysis emission end point energy error example filter frequency galvanometer gas chromatography glass grid incident input instrument intensity ionization ions layer liquid measurement mercury metal meter method mixture molecules obtained operation optical optical rotation output oxidized particles pH meter photometer phototube plate current platinum polarized polarographic potential potentiometer precision prism procedure quantitative radiation range reaction reflection refractive index region resistance resistor result rotation sample sawtooth wave scattering schematic Section sensitivity shown in Fig signal slit solution solvent species spectra spectrophotometer spectrum standard substance techniques temperature thyratron tion titration transistor triode variable vibrational voltage wave wavelength