Chemical Instrumentation: A Systematic Approach to Instrumental AnalysisAddison-Wesley Publishing Company, 1960 - 653 pagine |
Dall'interno del libro
Risultati 1-3 di 88
Pagina 267
... electrical and electrochemical properties of matter is useful in identification of substances and in the determination of the composition of mixtures . Their determination re- quires devising appropriate electrical and electronic ...
... electrical and electrochemical properties of matter is useful in identification of substances and in the determination of the composition of mixtures . Their determination re- quires devising appropriate electrical and electronic ...
Pagina 268
... electrical - frequency range , the mag- netic effects are often small and may be conveniently ignored . Instances in which magnetic fields play a significant role are not lacking , however . For example , as soon as a conductor is ...
... electrical - frequency range , the mag- netic effects are often small and may be conveniently ignored . Instances in which magnetic fields play a significant role are not lacking , however . For example , as soon as a conductor is ...
Pagina 298
... electrical neutrality are never great , for electrical and concentration gradients are effective in inducing ionic migration and diffusion , respectively . For example , if negative ions are in excess at an electrode surface as a result ...
... electrical neutrality are never great , for electrical and concentration gradients are effective in inducing ionic migration and diffusion , respectively . For example , if negative ions are in excess at an electrode surface as a result ...
Sommario
THE SCIENCE OF INSTRUMENTATION | 1 |
ERRORS OF MEASUREMENT | 14 |
CHAPTER 3 | 34 |
Copyright | |
39 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Chemical Instrumentation: A Systematic Approach to Instrumental Analysis Howard A. Strobel Visualizzazione estratti - 1960 |
Parole e frasi comuni
absorbance absorption acid amplifier analysis analyzed angle anode applied atoms band beam Beer's law calibration calomel capacitance capacitor cathode cell Chem chemical circuit components concentration conductance constant coulometric curve detection detector determined device diffusion diode dispersion drop effect electrical electrode electrolysis emission end point energy error example filter frequency galvanometer gas chromatography glass grid incident input instrument intensity ionization ions layer liquid measurement mercury metal meter method mixture molecules obtained operation optical optical rotation output oxidized particles pH meter photometer phototube plate current platinum polarized polarographic potential potentiometer precision prism procedure quantitative radiation range reaction reflection refractive index region resistance resistor result rotation sample sawtooth wave scattering schematic Section sensitivity shown in Fig signal slit solution solvent species spectra spectrophotometer spectrum standard substance techniques temperature thyratron tion titration transistor triode variable vibrational voltage wave wavelength