Chemical Instrumentation: A Systematic Approach to Instrumental AnalysisAddison-Wesley Publishing Company, 1960 - 653 pagine |
Dall'interno del libro
Risultati 1-3 di 65
Pagina 121
... prism table 45 ° 60 ° Το telescope lens FIG . 5-9 . Constant - deviation glass prism and mounting . This one - piece Pellin - Broca prism is equivalent to two 30 ° prisms cemented to a 45 ° totally reflecting prism . When a ...
... prism table 45 ° 60 ° Το telescope lens FIG . 5-9 . Constant - deviation glass prism and mounting . This one - piece Pellin - Broca prism is equivalent to two 30 ° prisms cemented to a 45 ° totally reflecting prism . When a ...
Pagina 238
... prism X and the refracting prism R. The prisms are partially hollowed to allow the circulation of thermostated fluid . Light enters from below , usually being reflected from a mirror . Two points should be especially noted . First , no ...
... prism X and the refracting prism R. The prisms are partially hollowed to allow the circulation of thermostated fluid . Light enters from below , usually being reflected from a mirror . Two points should be especially noted . First , no ...
Pagina 242
... prism . For liquid samples , the refracting prism is immersed almost completely . In the telescope the border between light and dark fields impinges on an accurately ruled scale in a filar micrometer eyepiece . The exact location of the ...
... prism . For liquid samples , the refracting prism is immersed almost completely . In the telescope the border between light and dark fields impinges on an accurately ruled scale in a filar micrometer eyepiece . The exact location of the ...
Sommario
THE SCIENCE OF INSTRUMENTATION | 1 |
ERRORS OF MEASUREMENT | 14 |
CHAPTER 3 | 34 |
Copyright | |
39 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Chemical Instrumentation: A Systematic Approach to Instrumental Analysis Howard A. Strobel Visualizzazione estratti - 1960 |
Parole e frasi comuni
absorbance absorption acid amplifier analysis analyzed angle anode applied atoms band beam Beer's law calibration calomel capacitance capacitor cathode cell Chem chemical circuit components concentration conductance constant coulometric curve detection detector determined device diffusion diode dispersion drop effect electrical electrode electrolysis emission end point energy error example filter frequency galvanometer gas chromatography glass grid incident input instrument intensity ionization ions layer liquid measurement mercury metal meter method mixture molecules obtained operation optical optical rotation output oxidized particles pH meter photometer phototube plate current platinum polarized polarographic potential potentiometer precision prism procedure quantitative radiation range reaction reflection refractive index region resistance resistor result rotation sample sawtooth wave scattering schematic Section sensitivity shown in Fig signal slit solution solvent species spectra spectrophotometer spectrum standard substance techniques temperature thyratron tion titration transistor triode variable vibrational voltage wave wavelength