Chemical Instrumentation: A Systematic Approach to Instrumental AnalysisAddison-Wesley Publishing Company, 1960 - 653 pagine |
Dall'interno del libro
Risultati 1-3 di 83
Pagina 319
... region . C , saturation region . Cathode Distance 0 Anode FIG . 12-4 . Variation in several pa- rameters for a diode under conditions where space charge governs behavior . Q , space charge density . V , potential . E , field strength ...
... region . C , saturation region . Cathode Distance 0 Anode FIG . 12-4 . Variation in several pa- rameters for a diode under conditions where space charge governs behavior . Q , space charge density . V , potential . E , field strength ...
Pagina 364
... region , when the p - type material is positive and the n - type is negative . In Fig . 12-42 ( a ) the movement of majority charge carriers under this biasing is illustrated schematically . Attracted by the potentials set up , holes ...
... region , when the p - type material is positive and the n - type is negative . In Fig . 12-42 ( a ) the movement of majority charge carriers under this biasing is illustrated schematically . Attracted by the potentials set up , holes ...
Pagina 477
... region it will change sharply enough to establish the equivalence point with precision . The data in Table 15–5 illustrate the variation in emf response in the end - point regions of two representative titrations in which there are ...
... region it will change sharply enough to establish the equivalence point with precision . The data in Table 15–5 illustrate the variation in emf response in the end - point regions of two representative titrations in which there are ...
Sommario
THE SCIENCE OF INSTRUMENTATION | 1 |
ERRORS OF MEASUREMENT | 14 |
CHAPTER 3 | 34 |
Copyright | |
39 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Chemical Instrumentation: A Systematic Approach to Instrumental Analysis Howard A. Strobel Visualizzazione estratti - 1960 |
Parole e frasi comuni
absorbance absorption acid amplifier analysis analyzed angle anode applied atoms band beam Beer's law calibration calomel capacitance capacitor cathode cell Chem chemical circuit components concentration conductance constant coulometric curve detection detector determined device diffusion diode dispersion drop effect electrical electrode electrolysis emission end point energy error example filter frequency galvanometer gas chromatography glass grid incident input instrument intensity ionization ions layer liquid measurement mercury metal meter method mixture molecules obtained operation optical optical rotation output oxidized particles pH meter photometer phototube plate current platinum polarized polarographic potential potentiometer precision prism procedure quantitative radiation range reaction reflection refractive index region resistance resistor result rotation sample sawtooth wave scattering schematic Section sensitivity shown in Fig signal slit solution solvent species spectra spectrophotometer spectrum standard substance techniques temperature thyratron tion titration transistor triode variable vibrational voltage wave wavelength