Principles of Instrumental AnalysisSaunders College Pub., 1998 - 849 pagine This text is written for a course that deals with the principles and applications of modern analytical instruments. Emphasis is placed upon the theoretical basis of each type of instrument, its optimal area of application, its sensitivity, its precision, and its limitations. The text also introduces students to elementary integrated circuitry, microprocessors and computers, and treatment of analytical data. |
Dall'interno del libro
Risultati 1-3 di 69
Pagina 46
... cathode - ray tube as a readout device . Both analog and digital oscilloscopes are manufactured . Digital ... cathode - ray tube . Unregulated Zener dc input Regulated diode dc input Figure 2-24 A Zener stabilized voltage regulator ...
... cathode - ray tube as a readout device . Both analog and digital oscilloscopes are manufactured . Digital ... cathode - ray tube . Unregulated Zener dc input Regulated diode dc input Figure 2-24 A Zener stabilized voltage regulator ...
Pagina 215
... cathode Glass shield Ne or Ar at 1-5 torr Quartz or Pyrex window Figure 9-11 Schematic cross section of a hollow cathode lamp . Hollow Cathode Lamps The most common source for atomic absorption mea- surements is the hollow cathode lamp ...
... cathode Glass shield Ne or Ar at 1-5 torr Quartz or Pyrex window Figure 9-11 Schematic cross section of a hollow cathode lamp . Hollow Cathode Lamps The most common source for atomic absorption mea- surements is the hollow cathode lamp ...
Pagina 637
... cathode potential electrolysis . ( b ) If any separations are feasible , evaluate the range ( vs. SCE ) within which the cathode potential should be controlled for the deposition of each . ( c ) Calculate the potential ( vs. SCE ) ...
... cathode potential electrolysis . ( b ) If any separations are feasible , evaluate the range ( vs. SCE ) within which the cathode potential should be controlled for the deposition of each . ( c ) Calculate the potential ( vs. SCE ) ...
Sommario
Contents CHAPTER 1 Introduction | 1 |
1D Selecting an Analytical Method | 11 |
1F Questions and Problems | 18 |
Copyright | |
61 sezioni non visualizzate
Parole e frasi comuni
absorbance absorption acid amplifier Anal analysis analyte anode applications atomic band beam Beer's law Calculate capillary carbon cathode cell Chem chemical chro chromatography circuit column components compounds concentration constant coulometric curve detection detector determination device difference elec electrical elements emission energy Equation example excited filter flow fluorescence Fourier transform frequency function gas chromatography hydrogen infrared input instruments ionization ions iron(III laser lines liquid magnetic mass spectrometry measurements metal methods mobile phase molecular molecules monochromator operational amplifier optical output oxidation peak photomultiplier plasma polarization polarography protons pulse quantitative radiation Raman Raman spectroscopy range ratio reaction reagent region relative sample scan Section shown in Figure signal slit solution solvent species spectra spectrometer spectrophotometers spectroscopy spectrum standard deviation supercritical fluid surface technique temperature thermal tion titration transducer tube typical ultraviolet vibrational voltage wavelength wavenumber Wiley X-ray