Chemical Instrumentation: A Systematic ApproachWiley, 22 feb 1989 - 1248 pagine The Third Edition of this established work on chemical instrumentation has been completely rewritten and updated to account for the advances made since the Second Edition came out in 1973. More main methods of measurement are presented, and there is extended coverage of chromatography and electrochemistry. Most of the material is new--including coverage of microprocessors and microcomputers, statistical control of measurement quality, quantification and extraction of information, x-ray fluorescence spectrometry, surface spectrometric techniques, and chromatography and HPLC. The quality and range of the worked examples have been improved, and there are end-of-chapter exercises. |
Dall'interno del libro
Risultati 1-3 di 77
Pagina 383
... analyte sample channels can be evaluated are : 1. Resolution . Is an analyte presented for measurement under conditions that ensure at least that its response will have minimum overlap with the re- sponses of other constituents ? 2 ...
... analyte sample channels can be evaluated are : 1. Resolution . Is an analyte presented for measurement under conditions that ensure at least that its response will have minimum overlap with the re- sponses of other constituents ? 2 ...
Pagina 576
... analyte peak is overlapped by a large interfering peak . ( a ) Absorbance curves for analyte peak A and composite peak B. ( b ) A ' , B ' , first derivatives of the two absorbance curves . The vertical distance HA ( between the maximum ...
... analyte peak is overlapped by a large interfering peak . ( a ) Absorbance curves for analyte peak A and composite peak B. ( b ) A ' , B ' , first derivatives of the two absorbance curves . The vertical distance HA ( between the maximum ...
Pagina 922
... analyte ? Assume that measurements with standards have confirmed the reproducibility of the GC and column for the analyte . Actually , it can be shown that two compounds can have the same retention time under particular conditions ...
... analyte ? Assume that measurements with standards have confirmed the reproducibility of the GC and column for the analyte . Actually , it can be shown that two compounds can have the same retention time under particular conditions ...
Sommario
Measurement and Instrumentation | 1 |
Operational Amplifier Circuits | 4 |
BASIC ELECTRONICS | 21 |
Copyright | |
29 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Chemical Instrumentation: A Systematic Approach Howard A. Strobel,William R. Heineman Visualizzazione estratti - 1989 |
Parole e frasi comuni
absorbance absorption amplifier amplitude analyte analytical signal angle atomic band beam Beer's law bits capacitor cell Chem circuit components concentration constant curve detector device diagram differential diffraction diffraction grating diode dispersion electrical electronic elements emission energy ensure equation error example excited exit slit feedback filter flame flip-flop fluorescence frequency gate grating incident input instrument integrated integrated circuit intensity interference lamp laser limit measurements method microprocessor mirror mode modules molecules monochromator noise Ohm's law op-amp operation operational amplifier optical output voltage p-n junction peak photodiode photomultiplier photon polarized precision prism pulse R₁ R₂ radiation Raman range reflection refractive index region resistance resistor resolution result sample scanning Section shown in Fig signal slit width spectral spectrometer spectrophotometer spectrum standard stray light temperature transistor transition tube V₁ variable vibrational wave wavelength wavenumber zener diode