Chemical Instrumentation: A Systematic ApproachWiley, 22 feb 1989 - 1248 pagine The Third Edition of this established work on chemical instrumentation has been completely rewritten and updated to account for the advances made since the Second Edition came out in 1973. More main methods of measurement are presented, and there is extended coverage of chromatography and electrochemistry. Most of the material is new--including coverage of microprocessors and microcomputers, statistical control of measurement quality, quantification and extraction of information, x-ray fluorescence spectrometry, surface spectrometric techniques, and chromatography and HPLC. The quality and range of the worked examples have been improved, and there are end-of-chapter exercises. |
Dall'interno del libro
Risultati 1-3 di 55
Pagina 483
... flame is protected against the unsettling diffusion of air , the outer slots providing a type of peripheral flame curtain . There are two possible disadvantages of a premix burner . When a solvent mix- ture such as alcohol - water ( see ...
... flame is protected against the unsettling diffusion of air , the outer slots providing a type of peripheral flame curtain . There are two possible disadvantages of a premix burner . When a solvent mix- ture such as alcohol - water ( see ...
Pagina 484
... flame , the more effective the process . Flames must also be stable and something must be known about the background levels of chemical species derived from the flame gases as well as those derived from the sample . Not all parts of a flame ...
... flame , the more effective the process . Flames must also be stable and something must be known about the background levels of chemical species derived from the flame gases as well as those derived from the sample . Not all parts of a flame ...
Pagina 487
... Flame Atomization " Type of Error 1. Chemical ( or cation and anion ) inter- ference 2. Background ( or nonspecific ) ... flame ; AA , FE , AF ( a ) Emission by flame gases ; FE ( much less important for AA and AF ) ; emission by analyte ...
... Flame Atomization " Type of Error 1. Chemical ( or cation and anion ) inter- ference 2. Background ( or nonspecific ) ... flame ; AA , FE , AF ( a ) Emission by flame gases ; FE ( much less important for AA and AF ) ; emission by analyte ...
Sommario
Measurement and Instrumentation | 1 |
Operational Amplifier Circuits | 4 |
BASIC ELECTRONICS | 21 |
Copyright | |
29 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Chemical Instrumentation: A Systematic Approach Howard A. Strobel,William R. Heineman Visualizzazione estratti - 1989 |
Parole e frasi comuni
absorbance absorption amplifier amplitude analyte analytical signal angle atomic band beam Beer's law bits capacitor cell Chem circuit components concentration constant curve detector device diagram differential diffraction diffraction grating diode dispersion electrical electronic elements emission energy ensure equation error example excited exit slit feedback filter flame flip-flop fluorescence frequency gate grating incident input instrument integrated integrated circuit intensity interference lamp laser limit measurements method microprocessor mirror mode modules molecules monochromator noise Ohm's law op-amp operation operational amplifier optical output voltage p-n junction peak photodiode photomultiplier photon polarized precision prism pulse R₁ R₂ radiation Raman range reflection refractive index region resistance resistor resolution result sample scanning Section shown in Fig signal slit width spectral spectrometer spectrophotometer spectrum standard stray light temperature transistor transition tube V₁ variable vibrational wave wavelength wavenumber zener diode