Analytical ChemistryWiley, 14 mar 2003 - 848 pagine Extensively revised and updated with a more modern flavor and a new, two-color design, this sixth edition deals with principles and techniques of quantitative analysis. Examples of analytical techniques are drawn from such areas as life sciences, clinical chemistry, air and water pollution, and industrial analyses. New to this edition: Excel spreadsheets on CD-ROM * New chapters on good laboratory practice, as well as genomics and proteomics * A more modern flavor. |
Dall'interno del libro
Risultati 1-3 di 5
Pagina 63
... Coulometric Calibration of Micropipets , " Microchem . J. , 9 ( 1965 ) 16 . 12. M. R. Masson , “ Calibration of Plastic Laboratory Ware , " Talanta , 28 ( 1981 ) 781. Tables for use in calibration of polypropylene vessels are presented ...
... Coulometric Calibration of Micropipets , " Microchem . J. , 9 ( 1965 ) 16 . 12. M. R. Masson , “ Calibration of Plastic Laboratory Ware , " Talanta , 28 ( 1981 ) 781. Tables for use in calibration of polypropylene vessels are presented ...
Pagina 118
... coulometric titration is 0.5 meq / L . What is the 95 % confidence limit for a trip- licate determination ? 24. Estimate the range of the true molarity of the solution at the 90 % confidence level from the standardization in Problem 31 ...
... coulometric titration is 0.5 meq / L . What is the 95 % confidence limit for a trip- licate determination ? 24. Estimate the range of the true molarity of the solution at the 90 % confidence level from the standardization in Problem 31 ...
Pagina 681
... coulometric titration with electrogenerated silver ion . Blood glucose and blood urea nitrogen ( BUN ) are probably the two most frequently performed clinical tests . In the procedures described in Table 24.2 , the total of all reducing ...
... coulometric titration with electrogenerated silver ion . Blood glucose and blood urea nitrogen ( BUN ) are probably the two most frequently performed clinical tests . In the procedures described in Table 24.2 , the total of all reducing ...
Sommario
Chapter | 1 |
The use of spreadsheets for plotting curves and perform Least squares equation | 3 |
Chapter | 8 |
Copyright | |
38 sezioni non visualizzate
Parole e frasi comuni
absorbance absorption acetic acid acid solution activity coefficients AgCl agent amount analysis Analytical Chemistry atomic balance base buffer buret Ca2+ calcium Calculate the pH calibration cell centration Chapter chelate Chem chemical chloride chromatography color column complex concentration detector determined dilute dissociation dissolved EDTA electrolyte end point equal Equation equilibrium constant equivalence point error example f wt Fe2+ filter flask formula weight glass gravimetric half-reaction HOAc hydrogen ion hydroxide indicator ion-selective electrode ionic strength ionization iron(III laboratory liquid measurements membrane metal ion method millimoles mmol mmol/mL molarity molecules moles NaOH Nernst equation oxidizing pipet plot potassium potential precipitate prepared proton radiation ratio react reaction reagent redox reference electrode salt sample silver sodium sodium hydroxide solubility solvent species spreadsheet standard deviation substance temperature tion titration curve volume volumetric wavelength weak acid