Manual of Clinical MicrobiologyASM Press, 1999 - 1773 pagine For three decades the Manual of Clinical Microbiology has been recognized as the benchmark – the gold standard – for excellence among diagnostic microbiology books. That tradition of quality continues with the publication of the new seventh edition. Once again MCM provides all microbiologists, laboratorians, and infectious disease professionals with the definitive reference work for running an effective, state–of–the–art diagnostic laboratory. No other single resource offers such extensive, up–to–date, practical information presented in a concise and easily accessible format. MCM continues to set the standard for reliability and day–to–day utility as a reference work for all busy professionals in the diagnostic laboratory and infectious disease communities. Guiding the clinical microbiologist in the selection, performance, and interpretation of laboratory procedures, MCM focuses on the when and why of diagnostic procedures, as well as the how. It presents a direct approach to organizing information with thorough but concise treatments of all the major areas of microbiology, including new microbial discoveries, changing diagnostic methods, and emerging therapeutic challenges facing clinicians. |
Dall'interno del libro
Risultati 1-3 di 79
Pagina 60
... Sterile tube Sterile saline None Skin ulcer ( 29 ) 1. Obtain scrapings or biopsy specimens of the active margin of cutaneous or mucocutaneous ulcers . A punch biopsy specimen is recommended . 2. Place the sample in a sterile tube ...
... Sterile tube Sterile saline None Skin ulcer ( 29 ) 1. Obtain scrapings or biopsy specimens of the active margin of cutaneous or mucocutaneous ulcers . A punch biopsy specimen is recommended . 2. Place the sample in a sterile tube ...
Pagina 426
... sterile water and sterile saline or 0.2 % sterile BSA fraction V. Procedure 1. Collect 10 ml or less of sputum in a 50 - ml screw - cap centri- fuge tube . 2. Inside a BSC , add an equal volume of CPC - NaCl , cap se- curely , and shake ...
... sterile water and sterile saline or 0.2 % sterile BSA fraction V. Procedure 1. Collect 10 ml or less of sputum in a 50 - ml screw - cap centri- fuge tube . 2. Inside a BSC , add an equal volume of CPC - NaCl , cap se- curely , and shake ...
Pagina 1388
... sterile serologic pipette , carefully transfer all but 0.5 ml of the supernatant to a sterile tube , and store the tube at 4 ° C for possible future use . Mix the sediment with the remaining fluid . With a sterile Pasteur pipette ...
... sterile serologic pipette , carefully transfer all but 0.5 ml of the supernatant to a sterile tube , and store the tube at 4 ° C for possible future use . Mix the sediment with the remaining fluid . With a sterile Pasteur pipette ...
Sommario
GENERAL ISSUES IN CLINICAL | 1 |
SECTION VIII | 3 |
Molecular Detection and Identification of 23 Bacillus and Recently Derived | 13 |
Copyright | |
94 sezioni non visualizzate
Altre edizioni - Visualizza tutto
Parole e frasi comuni
acid activity addition agar agents allow amplification anaerobic analysis antibody antigen application approach appropriate assay associated aureus bacteria blood cause cell culture changes Clin clinical coli collection common concentration containing cost detection determine developed devices diagnosis direct disease disinfection effective enzyme epidemiologic evaluation examined example factors fluid fragments gene genetic hospital host human identification important increase incubated indicate infection inoculated isolates laboratory limited Manual medium methods microbial Microbiol Microbiology molecular occur organisms outbreak parasites pathogens patients performed positive preparation Prevention probe problem procedures rapid reaction reference reported resistance restriction routine samples selective sequences single skin species specimens standard Staphylococcus sterilization strains streptococci studies surface swab Table techniques tion tissue transport tube typing United urine usually virus viruses