" Code, will not permit arcs, sparks or heat otherwise generated or liberated inside of the enclosure, to cause ignition of exterior accumulations or atmospheric suspensions of a specified dust on or in the vicinity of the enclosure. "
Instrument Engineers' Handbook, Volume Two: Process Control and Optimization - Pagina xxxiv
a cura di - 2018 - 2464 pagine
Anteprima limitata - Informazioni su questo libro

Electrical Installations in Hazardous Locations

Peter J. Schram, Mark W. Earley - 1997 - 332 pagine
...dust or amounts that might affect performance or ratings. It is designed so that it will not permit arcs, sparks, or heat otherwise generated or liberated inside of the enclosure to cause ignition of exterior accumulations or atmospheric suspensions of a specified dust on or in...
Anteprima limitata - Informazioni su questo libro

Instrument Engineers' Handbook, Volume Two: Process Control and Optimization

Bela G. Liptak - 2018 - 2464 pagine
...and hydrocarbons. Dielectric Compensation Dielectric Constant A scheme by which changes in insulating liquid composition or temperature can be prevented...Elevation Elevation, Zero Emissivity or Emittance (£) A matrix built from step responses to predict the changes in the process output that result from...
Anteprima limitata - Informazioni su questo libro

User's Guide to the National Electrical Code

H. Brooke Stauffer - 2004 - 324 pagine
...apparatus. Dust-Ignitionproof. Equipment enclosed in a manner that excludes dusts and does not permit arcs, sparks, or heat otherwise generated or liberated inside of the enclosure to cause ignition of exterior accumulations or atmospheric suspensions of a specified dust on or in...
Anteprima limitata - Informazioni su questo libro

NFPA's Illustrated Dictionary of Electrical Terms

H. Brooke Stauffer - 2004 - 308 pagine
...Receptacle. Dust-Ignitionproof. Equipment enclosed in a manner that excludes dusts and does not permit arcs, sparks, or heat otherwise generated or liberated inside of the enclosure to cause ignition of exterior accumulations or atmospheric suspensions of a specified dust on or in...
Anteprima limitata - Informazioni su questo libro

Electrical Inspection Manual with Checklists

Jeffrey Sargent, Noel Williams - 2006 - 516 pagine
...Dust-Ignitionproof: [Definition from 500.2] Equipment enclosed in a manner that excludes dusts and does not permit arcs, sparks, or heat otherwise generated or liberated inside of the enclosure to cause ignition of exterior accumulations or atmospheric suspensions of a specified dust on or in...
Anteprima limitata - Informazioni su questo libro

User's Guide to the National Electrical Code® 2005

H. Brooke Stauffer - 2005 - 360 pagine
...apparatus. Dust-Ignitionproof. Equipment enclosed in a manner that excludes dusts and does not permit arcs, sparks, or heat otherwise generated or liberated inside of the enclosure to cause ignition of exterior accumulations or atmospheric suspensions of a specified dust on or in...
Anteprima limitata - Informazioni su questo libro

NFPA's Pocket Dictionary of Electrical Terms

H. Brooke Stauffer - 2005 - 292 pagine
...Receptacle. Dust-lgnitionproof. Equipment enclosed in a manner that excludes dusts and does not permit arcs, sparks, or heat otherwise generated or liberated inside of the enclosure to cause ignition of exterior accumulations or atmospheric suspensions of a specified dust on or in...