Understanding The Human Machine: A Primer For BioengineeringWorld Scientific Publishing Company, 7 ott 2004 - 412 pagine This introductory book for undergraduate students poses a question: What is bioengineering all about? After offering a reference frame and defining the objectives (chapter 1), “physiology” (chapter 2) is presented as a source material followed by “signals” (chapter 3) and “signal pick up” (chapter 4). Chapter 5 deals with the biological amplifier. Reading the signal and the need for mathematical models are the subject matter, respectively, of chapters 6 and 7; they only provide guidance. The last chapter tries to look ahead. Sometimes, the subject is treated in relative depth; at times, the visit is more superficial. Formation rather than information is favored. Historical shots supply background material and spicy insights. Style is light, sprinkled with a little humor. There are exercises which allow students to learn independently. |
Dall'interno del libro
Risultati 1-5 di 22
Pagina 30
... node (Figure 2.6), the Continuity Principle applied to blood (as carrier, in mLblood/min) and oxygen (as transported substance, in mLO2/mLblood) establishes in the steady state condition that, F[V]+ F. - FIA| ImEO2/min) (2.12) where [V] ...
... node (Figure 2.6), the Continuity Principle applied to blood (as carrier, in mLblood/min) and oxygen (as transported substance, in mLO2/mLblood) establishes in the steady state condition that, F[V]+ F. - FIA| ImEO2/min) (2.12) where [V] ...
Pagina 31
... node. After all, recall that current is nothing but amount of electric charge per unit time (1 amp = 1 coulomb/s) and in eq. (2.12) we have amount of oxygen also per unit time. The numerator in eq. (2.13) is usually obtained from a ...
... node. After all, recall that current is nothing but amount of electric charge per unit time (1 amp = 1 coulomb/s) and in eq. (2.12) we have amount of oxygen also per unit time. The numerator in eq. (2.13) is usually obtained from a ...
Pagina 38
Hai raggiunto il limite di visualizzazione per questo libro.
Hai raggiunto il limite di visualizzazione per questo libro.
Pagina 39
Hai raggiunto il limite di visualizzazione per questo libro.
Hai raggiunto il limite di visualizzazione per questo libro.
Pagina 69
Hai raggiunto il limite di visualizzazione per questo libro.
Hai raggiunto il limite di visualizzazione per questo libro.
Sommario
1 | |
13 | |
What They Are | 217 |
4 Signal Pick Up | 271 |
5 Biological Amplifier | 299 |
Reading the Signals | 337 |
The Need of Mathematical Models | 349 |
8 Rounding Up and Looking Ahead | 359 |
References | 365 |
Index | 383 |
List of Figures | 393 |
Altre edizioni - Visualizza tutto
Understanding the Human Machine: A Primer for Bioengineering Max E. Valentinuzzi Anteprima limitata - 2004 |
Understanding the Human Machine: A Primer for Bioengineering Max E. Valentinuzzi Anteprima limitata - 2004 |
Parole e frasi comuni
action potential activity amplifier amplitude aortic arterial atrial basic Bioengineering biological Biomedical Engineering biosensors block blood flow blood pressure body brain called capacitance capillaries cardiac cardiovascular cells channel Chapter circadian rhythms circuit clinical common mode complex concentration concept contraction depolarization detected differential electrical electrodes electrophysiology equation example experimental extracellular fluid feedback fibers Figure fluid frequency function Geddes gland glucose heart heart sounds hormone hypothalamic impedance increase input instrumentation amplifier insulin interface intestine ionic ions kidneys latter loop magnetic mathematical measured mechanical melatonin membrane potential mmHg negative nerve neural neurons node noise normal obtained oocyte output permeability physiology plasma potassium produce pulmonary recorded renal resistors respectively respiratory response sample secretion shows signal sinus sinus venosus skeletal muscle sodium solution stimulation student Study subject substances surface temperature tion tissue transducer Valentinuzzi valve venous ventricle ventricular voltage volume zero