Fundamentals of Analytical ChemistrySaunders College Pub., 1988 - 894 pagine |
Dall'interno del libro
Risultati 1-3 di 82
Pagina 53
... analyses , to have a stan- dard deviation s → σ = 2.4 μg / mL . Calculate the 80 and 95 % confidence intervals for the result , 18.5 μg Fe / mL , if it was based upon ( a ) a single analysis , ( b ) the mean of two analyses , ( c ) the ...
... analyses , to have a stan- dard deviation s → σ = 2.4 μg / mL . Calculate the 80 and 95 % confidence intervals for the result , 18.5 μg Fe / mL , if it was based upon ( a ) a single analysis , ( b ) the mean of two analyses , ( c ) the ...
Pagina 808
... Analysis . This annual publication consists of a series of review articles covering the newest developments in the analysis of biochemical substances . Tabular Compilations E. Hoegfeldt and D. D. Perrin , Stability Constants of Metal ...
... Analysis . This annual publication consists of a series of review articles covering the newest developments in the analysis of biochemical substances . Tabular Compilations E. Hoegfeldt and D. D. Perrin , Stability Constants of Metal ...
Pagina 876
... analysis , 800 ; least - squares evaluation of , 39-42 ; for polarographic analysis , 441 Calibration standards , for absorp- tion analysis , 516 ; for chemical analysis , 5 ( see also Primary stan- dards ) ; for chromatographic ...
... analysis , 800 ; least - squares evaluation of , 39-42 ; for polarographic analysis , 441 Calibration standards , for absorp- tion analysis , 516 ; for chemical analysis , 5 ( see also Primary stan- dards ) ; for chromatographic ...
Sommario
Introduction | 1 |
Evaluation of Analytical Data | 6 |
Gravimetric Methods of Analysis | 57 |
Copyright | |
63 sezioni non visualizzate
Parole e frasi comuni
absorbance absorption acetic activity coefficients addition AgNO3 aliquot analysis analytical concentration anode applications aqueous solution atoms autoprotolysis base bromocresol green buffer Calculate the pH carbonate cathode cations cell cell potential cerium(IV chemical chromatography color column complex compounds conjugate base coulometric Cu2+ detector determination dilute dissociation constant dissolved EDTA electrolyte end point Equation equilibrium constant equivalence point error example excess Fe3+ filter formation constant H₂O H3O+ half-reaction hydronium ion concentration indicator iodine ionic strength iron(II K₁ KMnO4 liquid measurements metal method mmol mobile phase molar concentration molecules NaOH obtained oxidation particles potassium precipitate quantity radiation ratio reaction reagent relative sample shown in Figure silver silver chloride sodium solid solubility solution containing solvent species standard deviation standard electrode potentials standard hydrogen electrode standard solution Substitution Table temperature titration titration curves volume volumetric wavelength weak acid weight Zn2+