Fundamentals of Analytical ChemistrySaunders College Pub., 1988 - 894 pagine |
Dall'interno del libro
Risultati 1-3 di 60
Pagina 159
... saturated with CaF2 . * ( e ) 0.100 M in NaOH and saturated with Zn ( OH ) 2 ( which undergoes the reaction Zn ( OH ) 2 + 20H ̄ = Zn ( OH ) 2 ̄ ) . ( f ) saturated with MgCO3 . * ( g ) saturated with CaF2 . ( h ) 0.010 M in NaF and ...
... saturated with CaF2 . * ( e ) 0.100 M in NaOH and saturated with Zn ( OH ) 2 ( which undergoes the reaction Zn ( OH ) 2 + 20H ̄ = Zn ( OH ) 2 ̄ ) . ( f ) saturated with MgCO3 . * ( g ) saturated with CaF2 . ( h ) 0.010 M in NaF and ...
Pagina 160
... saturated solution is 1.17 x 105 M in OH ̄ . A 0.040 M KI solution saturated with PbI , is found to be 4.44 x 10-6 M in Pb2 + . Calculate K , for Pbl2 . Calculate the solubility - product constant for La ( IO3 ) 3 if a saturated ...
... saturated solution is 1.17 x 105 M in OH ̄ . A 0.040 M KI solution saturated with PbI , is found to be 4.44 x 10-6 M in Pb2 + . Calculate K , for Pbl2 . Calculate the solubility - product constant for La ( IO3 ) 3 if a saturated ...
Pagina 358
... saturated calomel electrode is 0.2444 V at 25 ° C . The saturated calomel electrode shown in Figure 15-1 is typical of elec- trodes obtainable from commercial sources . It consists of a 5- to 15 - cm tube that is 0.5 to 1.0 cm in ...
... saturated calomel electrode is 0.2444 V at 25 ° C . The saturated calomel electrode shown in Figure 15-1 is typical of elec- trodes obtainable from commercial sources . It consists of a 5- to 15 - cm tube that is 0.5 to 1.0 cm in ...
Sommario
Introduction | 1 |
Evaluation of Analytical Data | 6 |
Gravimetric Methods of Analysis | 57 |
Copyright | |
63 sezioni non visualizzate
Parole e frasi comuni
absorbance absorption acetic activity coefficients addition AgNO3 aliquot analysis analytical concentration anode applications aqueous solution atoms autoprotolysis base bromocresol green buffer Calculate the pH carbonate cathode cations cell cell potential cerium(IV chemical chromatography color column complex compounds conjugate base coulometric Cu2+ detector determination dilute dissociation constant dissolved EDTA electrolyte end point Equation equilibrium constant equivalence point error example excess Fe3+ filter formation constant H₂O H3O+ half-reaction hydronium ion concentration indicator iodine ionic strength iron(II K₁ KMnO4 liquid measurements metal method mmol mobile phase molar concentration molecules NaOH obtained oxidation particles potassium precipitate quantity radiation ratio reaction reagent relative sample shown in Figure silver silver chloride sodium solid solubility solution containing solvent species standard deviation standard electrode potentials standard hydrogen electrode standard solution Substitution Table temperature titration titration curves volume volumetric wavelength weak acid weight Zn2+